S 18
Nominal Power Handling - 1000 W*
Continuous Power Handling - 2000 W**
Nominal Impedance - 4 or 8 Ohms
Frequency Range - 37 Hz – 150 Hz
Sensitivity - 97.5 dB
Max SPL (half space, continuous) - 128 dB/1m
Max SPL (half space, peak) - 135 dB/1m
Weight - 38 kg
Dimensions - (W x H x D) 570 x 542 x 677 mm
Recomended external DSP setting :
HPF - 40Hz, 24dB/oct (BTW)
LPF - 100Hz, 18dB/oct (BTW)
PEQ - 55Hz, +2dB, Q=2 (BELL)
​
* 2 hours test made with continuous pink noise signal (6 dB crest factor) within the range Fs-10Fs.
** Power on Continuous Program is defined as 3 dB greater than the Nominal rating.
​
S 15
Nominal Power Handling - 500 W*
Continuous Power Handling - 1000 W**
Nominal Impedance - 4 or 8 Ohms
Frequency Range - 46 Hz – 350 Hz
Sensitivity - 96 dB
Max SPL (half space, continuous) - 123 dB/1m
Max SPL (half space, peak) - 132 dB/1m
Weight - 26 kg
Dimensions - (W x H x D) 580 x 470 x 530 mm
Recomended external DSP setting:
HPF – 40 Hz, 18 dB/oct (BTW)
LPF – 100-150Hz, 18 dB/oct (BTW)
PEQ – 65 Hz, +3 dB, Q=3 (BELL)
​
* 2 hours test made with continuous pink noise signal (6 dB crest factor) within the range Fs-10Fs.
** Power on Continuous Program is defined as 3 dB greater than the Nominal rating.